Role of the Pulse Oximetry in the cardiologist's practice‌‌

Abstract

The study had two phases: the first phase of exploring the possibility of a computer pulse oximetry as a screening method for the diagnosis of respiratory disorders during sleep in patients with cardiac profile in steady-state conditions, the second - a screening study of prevalence of obstructive sleep apnea in the same category of patients. In a comparative study of two methods: cardiorespiratory monitoring (4 channels, held monitoring device «Kardiotekhnika-07», «Incart», Russian, and computer pulse oximetry device PulseOx 7500, SPO medical, Israel) included 70 patients (70% men and 30% of women), mean age 55,5±11,2 years. The sensitivity of the computed pulse oximetry in detecting disorders of breathing during sleep (number of episodes of more than 5 per hour, reducing the saturation of more than 3%) was 94,4%; specificity - 79,2%; positive predictive value - 91,1%; negative - 86,4%; accuracy - 87,7%. In a screening study included every fifth patient entering the Russian Cardiology Research and Production Complex MH of the Russian Federation. Patients of the departments of cardiovascular surgery, emergency cardiology department of chronic heart failure, patients with respiratory diseases COPD, asthma were excluded. Statistical analysis included 206 patients. Median age was 68,4±13,7 years, BMI - 32,9±5,5 kg/m2, 43,6% of men and 56,3% of women. From 5 to 15 events per hour was observed in 31,1% of patients, from 15 to 30 events/h - 31,1% and more than 30 events per hour - 23,9%. Thus, respiratory disorders of varying severity were in 77,4% randomly sampled in the study patients.

About the Authors

A. V. Aksenova
ФГБУ Российский кардиологический научно-производственный комплекс Минздрава России, Москва
Russian Federation


Ye. M. Yelfimova
ФГБУ Российский кардиологический научно-производственный комплекс Минздрава России, Москва
Russian Federation


P. V. Galitsin
ФГБУ Российский кардиологический научно-производственный комплекс Минздрава России, Москва
Russian Federation


Sh. B. Goriyeva
ФГБУ Российский кардиологический научно-производственный комплекс Минздрава России, Москва
Russian Federation


T. D. Bugayev
ФГБУ Российский кардиологический научно-производственный комплекс Минздрава России, Москва
Russian Federation


O. O. Mikhailova
ФГБУ Российский кардиологический научно-производственный комплекс Минздрава России, Москва
Russian Federation


A. Yu. Litvin
ФГБУ Российский кардиологический научно-производственный комплекс Минздрава России, Москва
Russian Federation


A. N. Rogoza
ФГБУ Российский кардиологический научно-производственный комплекс Минздрава России, Москва
Russian Federation


I. Ye. Chazova
ФГБУ Российский кардиологический научно-производственный комплекс Минздрава России, Москва
Russian Federation


References

1. Andrew L, Chesson at al. Practice Parameters for the Use of Portable Monitoring Devices in the Investigation of Suspected Obstructive Sleep Apnea in Adults SLEEP 2003; 26 (7).

2. Jaime Corral- Peñafiel, Jean-Louis Pepin, Ferran Barbe. Ambulatory monitoring in the diagnosis and management of obstructive sleep apnoea syndrome. Eur Respir Rev 2013; 22: 312-24. DOI: 10.1183/09059180.00004213

3. Буниатян М.С., Зелвеян П.А., Ощепкова Е.В., Рогоза А.Н. Возможности мониторной пульсоксиметрии для скрининговой диагностики синдрома апноэ/гипопноэ во сне. Терапевт. арх. 2002; 11: 90-4.

4. Nikolaus Netzer, Arn H. Eliasson, Cordula Netzer, David A. Kristo. Overnight Pulse Oximetry for Sleep-Disordered Breathing in Adults. CHEST 2001; 120 (2).

5. Gianfranco Parati, Carolina Lombardi, Jan Hednerc et al on behalf of the EU COST ACTION B26 members Position paper on the management of patients with obstructive sleep apnea and hypertension: Joint recommendations by the European Society of Hypertension, by the European Respiratory Society and by the members of European COST (COoperation in Scientific and Technological research) ACTION B26 on Obstructive Sleep Apnea J Hypertens 2012; 30: 633-46. DOI:10.1097/HJH.0b013e328350e53b

6. Practice Parameters for CPAP and Bilevel PAP-Kushida et al. SLEEP 2006; 29 (3).


Review

For citations:


Aksenova A.V., Yelfimova Ye.M., Galitsin P.V., Goriyeva Sh.B., Bugayev T.D., Mikhailova O.O., Litvin A.Yu., Rogoza A.N., Chazova I.Ye. Role of the Pulse Oximetry in the cardiologist's practice‌‌. Systemic Hypertension. 2014;11(4):26-30.

Views: 130


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2075-082X (Print)
ISSN 2542-2189 (Online)